banner
banner
banner

High Voltage Flood Lights

Patented Multi-function design, suitable for all working environments.
Rated Power: 1000W
Input Voltage: AC90-305, DC127-431
Color Temperature: 2700K-6500K
Lamp Efficiency: 130LM/W
Beam Angle: 15°, 20°, 30°, 40°, 60°, 120°, 140°x60°.
CRI: Ra>75
IP Grade: IP65/IP67
Bracket: Stainless Steel
Net Weight: 15KG
Warranty: 5 Years
Certificate: CE, RoHS, SAA, C-Tick, UL, DLC, CB, ISO:9001
Send Inquiry Download
  • Product Description

High Voltage Flood Lights - 1000W Industrial LED Solution

For big installations, Razorlux high voltage flood lights don't need step-down transformers because they can work with both AC90-305V and DC127-431V. The 1000W light has a brightness of 130,000 lumens and is waterproof up to IP67. There are long lines that need to be run through places like ports, mines, and industries. It has seven different beam angles and a set of stainless steel clamps for fixing it.

product-1-1

    product-1-1

    High Voltage Flood Lights Specifications

    FeatureSpecification
    Model NumberRGL-1000A
    Rated Power1000W
    Input VoltageAC100-305, DC127-431
    Color Temperature2700K-6500K
    Lamp Efficiency130LM/W
    Lumen Output130000LM
    Beam Angle15°, 20°, 30°, 40°, 60°, 120°, 140°x60°
    LensTempered Glass
    Working Temperature-40° - 60°/ 40F - 140F
    CRIRa>75
    IP GradeIP67
    IK RatingIK10
    LED ChipSamsung/Phillip
    LED DriverMeanwell
    HousingAluminum Alloy
    BracketStainless Steel
    Net Weight32KG
    Warranty5 Years
    CertificatesRMRS,CE, RoHS, SAA, C-Tick, UL, DLC, CB, ISO:9001
    More Available Powers90W,120W, 150W, 180W, 210W, 270W, 200W, 300W, 400W, 500W, 600W, 800W, 1000W, 1200W

    product-1-1

    Product Advantages

    Reduced Installation Costs

    Higher operating voltage means lower current draw. This allows:

    · Smaller gauge copper cables (30-40% cost reduction)

    · More fixtures per circuit breaker

    · Longer cable runs without voltage drop issues

    Example: A 500m cable run at 220V requires 50% less copper than equivalent 110V systems.

    Wide Voltage Compatibility

    The AC90-305V / DC127-431V input range handles:

    · Generator power fluctuations at remote sites

    · Regional grid variations (100-277V nominal)

    · Direct DC connection to solar/battery systems

    Built-in surge protection (10kV/20kV) guards against grid transients.

    product-1-1

    Application Scenarios

    We recommend upgrading the lighting system to High Voltage Flood Lights.

    Container Ports & Terminals

    ·Lighting for the landing yard from 25 to 50 m high poles

    · C5M covering that doesn't rust in salt spray settings

    ·The IP67 sealing can survive upkeep with high-pressure water cleaning.

    ·Mounting that doesn't shake for big places with cranes or vehicles

    Open-Pit Mining & Quarries

    ·Works reliably with unstable generator power

    ·IK08+ grade can handle strong noises and rock fragments

    ·It can be cold (-40°C in the winter) or hot (+55°C in the summer).

    · Long wire runs (more than 300m) with no voltage drop protection

    Manufacturing Facilities

    · High CRI (Ra >75) for checking the quality

    ·No flickering (less than 5% at 50,000 hours)

    ·Fast start in cold storage (no wait for equipment to warm up)

    ·0-10V and DALI (choose at checkout) are the dimming options.

    product-1-1

    Infrastructure Projects

    · Airports: apron lighting, taxiway illumination

    · Rail yards: shunting areas, maintenance depots

    · Logistics hubs: outdoor storage, loading docks

    · Highway toll plazas and service areas

    product-1-1

    product-1-1

    product-1-1

    Frequently Asked Questions

    What voltage should I specify for my project?

    Check your site's electrical system:

    · North America: Typically 120-277V AC (specify 200-305V input model)

    · Europe/Asia: 220-240V AC (200-305V model works)

    · DC solar/battery: Match system voltage (127-431V DC model)

    Our team provides free electrical load calculations—send site details to the contact email below.

    Can I use these in coastal/marine environments?

    Yes, with precautions:

    · Specify IP67 rating (vs. standard IP65)

    · C5M coating included for salt-mist resistance

    · Recommend 304 stainless steel hardware (standard)

    · Schedule annual bracket inspection for bolted connections

    What's the difference between IP65 and IP67?

    · IP65: Dust-tight, withstands water jets (standard for most industrial sites)

    · IP67: Dust-tight, withstands temporary immersion up to 1m (for flood-prone areas or washdown zones)

    Both ratings handle rain, snow, and pressure washing.

    Do you provide photometric layouts?

    Yes, free of charge. Send us:

    · Site dimensions and mounting height

    · Required lux levels

    · Obstructions (buildings, poles, equipment)

    We'll provide IES files and AGi32/Dialux simulations within 48 hours.

    What's the lead time for custom beam angles?

    · Standard angles (15°/30°/60°/120°): 2-3 weeks

    · Custom angles or CRI >80: 4-5 weeks

    Is dimming available?

    Yes, specify at order time (driver configuration required):

    · 0-10V analog dimming (10-100% range)

    · DALI digital dimming (requires DALI controller)

    Cannot retrofit dimming after manufacturing.

    Technical Support

    For project-specific questions, contact our engineering team:

    Email our High Voltage Flood Lights'team: sam@razorlux.com

    Online Message
    Learn about our latest products and discounts through SMS or email