1400 Watt Led Sports Light
Rated Power: 1400W
Input Voltage: AC80-315Vac
Color Temperature: 2700K-6500K
Lamp Efficiency: 130LM/W
Beam Angle: 15°, 20°, 30°.
CRI: Ra>75
IP Grade: IP65/IP67
Bracket: Stainless Steel
Net Weight: 38KG
Warranty: 5 Years
Certificate: CE, RoHS, SAA, C-Tick, UL, DLC, CB, ISO:9001
- Product Description
1400 Watt Led Sports Light – Professional Stadium Lighting for High-Performance VenuesEnterprise-Grade High-Intensity Sports Lighting Solution
For professional stadiums, training facilities, and multi-sport complexes, the Razorlux 1400 watt led sports light provides 182,000 lumens of strong illumination. This industrial-grade light replaces 3000–4000W metal halide systems and saves 60% on energy expenditures because to its 130LM/W efficiency and IP67 protection. 5-year guarantee with CE, UL, and DLC certification.
1400 Watt Led Sports Light Specifications

Model | RGL2-1400P | |
Beam Angle | 15° 20° 30° | |
Stable Flux (5700K after 1 hour) | 168000lm | |
| LEDs | 1260W |
Power | Driver | 140W |
Consumption | Total | 1400W |
Replace HID Lamp | 3000 ~ 3500 W | |
Net Weight | 38kg with stainless steel floodlight bracket | |
Color Temperature | 2700-6500K | |
Color Rendering | ≥Ra75 (≥Ra80, ≥Ra90 available on request) | |
Working Life | ≥50000Hrs | |
Housing Material | Aluminum & Powder coating | |
Power Supply | Meanwell | |
IP Class | IP 67 | |
IK Class | IK 10 | |
Insulation Class | Class I | |
Working Temperature | -40C ~ 60C / -40F ~ 140F | |
Working Humidity | 10% ~ 95% | |
AC Input | 80-315Vac input voltage without additional adapter | |
Power Factor | ≥0.98 | |
Warranty | LED Module | 5 year |
|
|
|
| Driver | 5 year |
| Housing | 10 year |

Why Razorlux 1400W LED Outperforms Traditional Stadium Lighting
Broadcast-Quality Illumination Meets Athletic Performance Standards
Flicker-free operation at 0.3% ensures crystal-clear high-speed video capture for 4K broadcasting and slow-motion replay. The high CRI (Ra>75) renders accurate colors critical for:
· Ball tracking in fast-paced sports (tennis, cricket, baseball)
· Team uniform differentiation under night conditions
· Meeting FIFA, UEFA, and NCAA lighting standards for competitive play
Precision beam control with 15°/20°/30° optics eliminates spill light, directing 95% of lumens onto the playing surface. This reduces light pollution complaints and complies with Dark Sky regulations.
Military-Grade Construction for Extreme Environments
IP67 rating provides complete protection against:
· Dust infiltration in arid climates
· Pressure washing during facility cleaning
· Heavy rain, snow, and coastal salt spray
C5M anti-corrosion certification (the highest marine-grade standard) ensures 15+ year lifespan in:
· Coastal stadiums within 500m of saltwater
· Industrial areas with chemical exposure
· High-humidity tropical regions
The marine-grade stainless steel bracket withstands wind loads up to 160 km/h, tested to IEC 60598 structural standards.

Universal Power Compatibility with Built-In Protection
AC 80-315V wide-range input adapts to:
· Unstable grid voltage in developing regions
· Industrial power fluctuations
· Generator-powered remote facilities
Integrated surge protection (10kV) safeguards against:
· Lightning strikes (common cause of stadium lighting failure)
· Grid switching transients
· Electrical storms
Application Scenarios & Lighting Design Guidance
Professional Sports Stadiums (Football, Soccer, Rugby)
Mounting height: 25-50 meters
Recommended configuration: 8-pole or 4-corner layout
Illumination target: 500-750 lux (Class I/II FIFA standard)
The 1400 watt led sports light provides 182,000 lumens, sufficient for:
· 20-meter pole spacing in training venues
· 100×70-meter field coverage with 12-16 fixtures
· Meeting HDTV broadcast requirements (1500 lux vertical)
Beam angle selection guide:
· 15° narrow beam: Poles >40m height
· 20° medium beam: 30-40m standard installations
· 30° wide beam: Multi-level lighting or low-mounting scenarios

Tennis & Racquet Sports Facilities
Critical requirements: Minimizing shadows and glare for fast ball tracking
Lighting design best practices:
· Mount fixtures at 12-15 meters on 4 corners
· Use 30° beam angle for uniform court coverage
· Target 300-500 lux average (ITF Class 3-4 standard)
· Select 5000K color temperature for enhanced ball visibility
Razorlux fixtures eliminate the 60Hz flicker that causes "stroboscopic effect" in HID lamps—a common complaint in racquet sports.
Multi-Purpose Sports Complexes
Flexible control for diverse activities:
Install with DALI or 0-10V dimming to adjust lighting levels:
· 100% output: Competitive matches, tournaments
· 70% output: Training sessions, recreational play
· 40% output: Maintenance mode, pathway lighting
Energy savings through smart dimming: A municipal sports complex reduced operating hours costs by additional 30% using automated scheduling.
Training Facilities & Practice Fields
Budget-conscious operations benefit from:
· Extended operational hours without prohibitive costs
· Minimal maintenance disruption (no bulb changes for 10+ years)
· Safe, shadow-free illumination for skill development
Recommended specification:
· 200-300 lux for amateur training
· 4000K neutral white for comfortable extended sessions
· 20° beam angle for standard 10-12 meter pole height
Industrial & Mining Sports Areas
Challenges addressed:
· Heavy dust exposure (IP67 rating prevents infiltration)
· Vibration from nearby machinery (solid-state LED unaffected)
· Voltage fluctuations (80-315V input range)
· Corrosive chemical environment (C5M-rated components)
No scheduled maintenance required for 36 months in typical industrial conditions.

Frequently Asked Questions
How long does the 50,000-hour lifespan translate to real-world use?
Usage scenarios:
· 10 hours/day operation = 13.7 years
· 8 hours/day operation = 17.1 years
· 5 hours/day operation = 27.4 years
The L70 rating means the fixture maintains 70% of initial lumens at end of rated life—still providing 127,400 lumens (sufficient for most applications).
Can I retrofit existing poles and electrical infrastructure?
Yes, in most cases:
· Standard mounting brackets fit poles with 60-120mm slip fitter
· AC 80-315V input eliminates need for new transformers
· Lower 1.4 kW draw reduces circuit loading (can add more fixtures per breaker)
· Lighter weight (38 kg vs. 55 kg for metal halide assemblies) reduces structural stress
Our technical team provides free lighting layout assessments to verify compatibility.
What dimming and control options are available?
Standard configurations:
· 0-10V analog dimming (10-100% range)
· DALI-2 digital control (1% granularity, individual fixture addressing)
· DMX512 for entertainment venue integration
Smart control benefits:
· Schedule-based automation (reduce output during off-peak)
· Daylight harvesting (auto-dimming at dusk/dawn)
· Emergency mode (maintain 40% output during power events)
Contact Us
Get a customized lighting design and ROI analysis for your facility:
Contact our 1400 watt led sports light's team: sam@razorlux.com

_1750326878398.png)





