1000 Watt Flood Light Outdoor
Rated Power: 1000W
Input Voltage: AC80~305Vac, DC100 ~ 400Vdc, 500Vdc ~ 800Vdc
Color Temperature: 2700K-6500K
Lamp Efficiency: 130LM/W
Beam Angle: 20°.
CRI: Ra>75
IP Grade: IP65/IP67
Bracket: Stainless Steel
Net Weight: 29KG
Warranty: 5 Years
Certificate: CE, RoHS, SAA, C-Tick, UL, DLC, CB, ISO:9001
- Product Description
1000 Watt Flood Light Outdoor – Industrial LED Lighting for Demanding Environments
Reliable high-power outdoor lighting demands performance under strain. Razorlux 1000 watt flood light outdoor 130,000 Lumens 130LM/W Efficiency for Ports, Stadiums, and Construction Sites Wide voltage compatibility (AC90-305V) takes care of fluctuating power circumstances, and the IP67 protection withstands adverse weather. 5 year guarantee backed by international certifications.
1000 Watt Flood Light Outdoor Specifications

Model | RGL-1000P-L20 | |
Beam Angle | 20° | |
Stable Flux (5700K after 1 hour) | 105,000lm | |
Dimension (mm) | 671*405*322 | |
| LEDs | 900W |
| Driver | 100W |
| Total | 1000W |
Replace HID Lamp | 2000~3000W | |
Net Weight | 29kg (66lbs) | |
Color Temperature | 2700-6500K | |
Color Rendering | ≥Ra75 (≥Ra80, ≥Ra90 available on request) | |
Working Life | ≥50000Hrs | |
Housing Material | Aluminum & Powder coating | |
Power Supply | Meanwell | |
IP Class | IP 65,IP 67 | |
IK Class | IK 10 | |
Insulation Class | Class I | |
Working Temperature | -40C ~ 60C / -40F ~ 140F | |
Working Humidity | 10% ~ 95% | |
AC Input | 80~305Vac | |
DC Input | 100 ~ 400Vdc, 500Vdc ~ 800Vdc | |
THD | <10% | |
Power Factor | ≥0.98 | |
Warranty | LED Module | 5 years |
| Driver | 5 years |
| Housing | 10 years |

Key Features
Wide Voltage Range for Unstable Power Conditions
AC90-305V input range accommodates:
· Remote construction sites with generator power
· Industrial facilities with voltage fluctuations
· International projects across different grid standards
· Backup power systems during emergencies
Tested to IEC 61000-4-5 standards for voltage surge immunity.
Advanced Thermal Management
Die-cast aluminum housing with optimized fin geometry maintains LED junction temperature below 85°C. Independent thermal testing shows:
· Less than 5% lumen depreciation after 10,000 hours
· Consistent color temperature throughout lifespan
· Extended driver component life in high-temperature environments

Precision Beam Control
Seven beam angle options match specific application requirements:
Beam Angle | Best For | Mounting Height |
15°-20° | Long-distance illumination | 25-40m high-mast |
30°-40° | Sports field coverage | 15-25m poles |
60°-120° | Area lighting, warehouses | 8-15m mounting |
140°x60° | Parking lots, walkways | 6-12m poles |
Photometric data available in IES format for lighting design software.
Marine-Grade Corrosion Protection
C5M classification for extreme corrosion environments:
· 1,000-hour salt spray test per ISO 9227
· Electrophoresis + powder coating process
· Stainless steel 304 mounting hardware
· Silicone gaskets for long-term seal integrity
Proven in installations across 30+ coastal ports globally.

Applications
Sports Stadiums & Training Facilities
Professional venues require uniform lighting for both athletes and broadcast cameras. Key performance metrics:
· Horizontal illuminance uniformity ≥0.7
· Vertical illuminance for HD/4K broadcasting
· Flicker-free operation (<1% at 50,000Hz)
· CRI >80 for accurate color rendering
Typical layout: 80-120 units for standard football pitch (Class I lighting).
Ports & Container Terminals
24/7 operations demand reliable lighting under harsh conditions:
· Salt spray and high humidity exposure
· Vibration from heavy equipment
· 30-40m high-mast installations
· Minimal light spill to surrounding areas
Energy savings: 60-70% compared to 2000W metal halide systems.
Airport Ground Operations
Ground support areas and hangars require:
· High CRI for accurate aircraft marking identification
· Wide voltage input for backup generator compatibility
· Weather resistance for outdoor apron lighting
· Rapid restrike (instant-on with LED technology)
Meets FAA and ICAO lighting recommendations for non-airfield lighting.
Construction & Mining Sites
Temporary or permanent installations face:
· Constant vibration and impact risks
· Extreme dust exposure (IP67 protection critical)
· Unreliable power infrastructure
· Temperature extremes (-40°C to +50°C operating range)
Portable installation option: Wheeled cart with adjustable tripod (sold separately).
Industrial Facilities
High-bay manufacturing and warehouses benefit from:
· Reduced fixture count (1 x 1000W replaces 3-4 x 400W HID)
· Lower maintenance costs (50,000+ hour lifespan)
· Improved productivity with better visibility
· Utility rebates through DLC Premium listing
ROI typically achieved within 18-24 months through energy savings.
Manufacturing Quality Control
Every 1000 watt flood light outdoor undergoes multi-stage testing:
1. Component Inspection
· Incoming LED bin tolerance verification (±3% flux)
· Driver component electrical parameter testing
2. Assembly Process Control
· Thermal compound application verification
· Torque specification for heat sink mounting
· Solder joint X-ray inspection (critical models)
3. Completed Unit Testing
· 4-hour burn-in at maximum rated voltage
· Thermal imaging to detect hot spots
· IP67 water immersion test (1m depth, 30 minutes)
· Photometric output verification in integrating sphere
4. Reliability Testing (Sample Basis)
· 10kV/20kV surge immunity per IEC 61000-4-5
· Salt spray testing: 1,000 hours continuous exposure
· Thermal cycling: -40°C to +50°C, 100 cycles

Frequently Asked Questions
Q: What metal halide wattage does this LED replace?
A: Typically replaces 2000-3000W metal halide systems, providing equal or better light levels with 60-70% energy reduction.
Q: Are dimming controls available?
A: Yes. Standard options include 0-10V analog dimming and DALI digital protocol. DMX control available for entertainment venues.
Q: What's the actual lifespan in operating hours?
A: Rated for 50,000+ hours to L70 (maintaining 70% of initial lumens). At 12 hours daily operation, this equals 11+ years.
Q: Can I use this in coastal environments?
A: Yes. C5M corrosion classification specifically designed for marine environments. Includes protective coating and stainless steel hardware.
Q: How often does this need maintenance?
A: Minimal maintenance required. Recommend annual inspection of mounting hardware and lens cleaning. Coastal installations: semi-annual cleaning to remove salt deposits.
Q: Can this operate in extreme temperatures?
A: Operating range: -40°C to +50°C. Tested for arctic and desert climates.
Get Project Support
For Technical Consultation:
· Photometric layout design
· Energy savings calculations
· Product selection assistance
· Certification documentation
For Ordering Information:
· Volume pricing
· Sample evaluation units
· Lead time confirmation
· Shipping logistics
Contact our 1000 watt flood light outdoor 's team: sam@razorlux.com

_1750326878398.png)












