banner
banner
banner

1000 Watt Flood Light Outdoor

Patented Multi-function design, suitable for all working environments.
Rated Power: 1000W
Input Voltage: AC80~305Vac, DC100 ~ 400Vdc, 500Vdc ~ 800Vdc
Color Temperature: 2700K-6500K
Lamp Efficiency: 130LM/W
Beam Angle: 20°.
CRI: Ra>75
IP Grade: IP65/IP67
Bracket: Stainless Steel
Net Weight: 29KG
Warranty: 5 Years
Certificate: CE, RoHS, SAA, C-Tick, UL, DLC, CB, ISO:9001
Send Inquiry Download
  • Product Description

1000 Watt Flood Light Outdoor – Industrial LED Lighting for Demanding Environments

Reliable high-power outdoor lighting demands performance under strain. Razorlux 1000 watt flood light outdoor 130,000 Lumens 130LM/W Efficiency for Ports, Stadiums, and Construction Sites Wide voltage compatibility (AC90-305V) takes care of fluctuating power circumstances, and the IP67 protection withstands adverse weather. 5 year guarantee backed by international certifications.1000 Watt Flood Light Outdoor

1000 Watt Flood Light Outdoor Specifications

Beam Angle & Installation Diagram

Model

RGL-1000P-L20

Beam Angle

20° 

Stable Flux (5700K after 1 hour)

105,000lm

Dimension (mm)

671*405*322


Power Consumption

LEDs

900W

 

Driver

100W

 

Total

1000W

Replace HID Lamp

2000~3000W

Net Weight

29kg (66lbs)

Color Temperature

2700-6500K

Color Rendering

≥Ra75 (≥Ra80, ≥Ra90 available on request)

Working Life

≥50000Hrs

Housing Material

Aluminum & Powder coating

Power Supply

Meanwell

IP Class

IP 65,IP 67

IK Class

IK 10

Insulation Class

Class I

Working Temperature

-40C ~ 60C / -40F ~ 140F

Working Humidity

10% ~ 95%

AC Input

80~305Vac

DC Input

100 ~ 400Vdc, 500Vdc ~ 800Vdc

THD

<10%

Power Factor

≥0.98

 

    Warranty

LED Module

5 years

 

Driver

5 years

 

Housing

10 years

Applications

Key Features

Wide Voltage Range for Unstable Power Conditions

AC90-305V input range accommodates:

· Remote construction sites with generator power

· Industrial facilities with voltage fluctuations

· International projects across different grid standards

· Backup power systems during emergencies

Tested to IEC 61000-4-5 standards for voltage surge immunity.

Advanced Thermal Management

Die-cast aluminum housing with optimized fin geometry maintains LED junction temperature below 85°C. Independent thermal testing shows:

· Less than 5% lumen depreciation after 10,000 hours

· Consistent color temperature throughout lifespan

· Extended driver component life in high-temperature environments

1000 Watt Flood Light Outdoor

Precision Beam Control

Seven beam angle options match specific application requirements:

Beam Angle

Best For

Mounting Height

15°-20°

Long-distance illumination

25-40m high-mast

30°-40°

Sports field coverage

15-25m poles

60°-120°

Area lighting, warehouses

8-15m mounting

140°x60°

Parking lots, walkways

6-12m poles

Photometric data available in IES format for lighting design software.

Marine-Grade Corrosion Protection

C5M classification for extreme corrosion environments:

· 1,000-hour salt spray test per ISO 9227

· Electrophoresis + powder coating process

· Stainless steel 304 mounting hardware

· Silicone gaskets for long-term seal integrity

Proven in installations across 30+ coastal ports globally.

1000 Watt Flood Light Outdoor

Applications

Sports Stadiums & Training Facilities

Professional venues require uniform lighting for both athletes and broadcast cameras. Key performance metrics:

· Horizontal illuminance uniformity ≥0.7

· Vertical illuminance for HD/4K broadcasting

· Flicker-free operation (<1% at 50,000Hz)

· CRI >80 for accurate color rendering

Typical layout: 80-120 units for standard football pitch (Class I lighting).

Ports & Container Terminals

24/7 operations demand reliable lighting under harsh conditions:

· Salt spray and high humidity exposure

· Vibration from heavy equipment

· 30-40m high-mast installations

· Minimal light spill to surrounding areas

Energy savings: 60-70% compared to 2000W metal halide systems.
Packaging and Transportation

Airport Ground Operations

Ground support areas and hangars require:

· High CRI for accurate aircraft marking identification

· Wide voltage input for backup generator compatibility

· Weather resistance for outdoor apron lighting

· Rapid restrike (instant-on with LED technology)

Meets FAA and ICAO lighting recommendations for non-airfield lighting.

Construction & Mining Sites

Temporary or permanent installations face:

· Constant vibration and impact risks

· Extreme dust exposure (IP67 protection critical)

· Unreliable power infrastructure

· Temperature extremes (-40°C to +50°C operating range)

Portable installation option: Wheeled cart with adjustable tripod (sold separately).

Industrial Facilities

High-bay manufacturing and warehouses benefit from:

· Reduced fixture count (1 x 1000W replaces 3-4 x 400W HID)

· Lower maintenance costs (50,000+ hour lifespan)

· Improved productivity with better visibility

· Utility rebates through DLC Premium listing

ROI typically achieved within 18-24 months through energy savings.

Packaging and TransportationManufacturing Quality Control

Every 1000 watt flood light outdoor undergoes multi-stage testing:

1. Component Inspection

· Incoming LED bin tolerance verification (±3% flux)

· Driver component electrical parameter testing

2. Assembly Process Control

· Thermal compound application verification

· Torque specification for heat sink mounting

· Solder joint X-ray inspection (critical models)

3. Completed Unit Testing

· 4-hour burn-in at maximum rated voltage

· Thermal imaging to detect hot spots

· IP67 water immersion test (1m depth, 30 minutes)

· Photometric output verification in integrating sphere

4. Reliability Testing (Sample Basis)

· 10kV/20kV surge immunity per IEC 61000-4-5

· Salt spray testing: 1,000 hours continuous exposure

· Thermal cycling: -40°C to +50°C, 100 cycles

Qualification Certification

Frequently Asked Questions

Q: What metal halide wattage does this LED replace?

A: Typically replaces 2000-3000W metal halide systems, providing equal or better light levels with 60-70% energy reduction.

Q: Are dimming controls available?

A: Yes. Standard options include 0-10V analog dimming and DALI digital protocol. DMX control available for entertainment venues.

Q: What's the actual lifespan in operating hours?

A: Rated for 50,000+ hours to L70 (maintaining 70% of initial lumens). At 12 hours daily operation, this equals 11+ years.

Q: Can I use this in coastal environments?

A: Yes. C5M corrosion classification specifically designed for marine environments. Includes protective coating and stainless steel hardware.

Q: How often does this need maintenance?

A: Minimal maintenance required. Recommend annual inspection of mounting hardware and lens cleaning. Coastal installations: semi-annual cleaning to remove salt deposits.

Q: Can this operate in extreme temperatures?

A: Operating range: -40°C to +50°C. Tested for arctic and desert climates.

Get Project Support

For Technical Consultation:

· Photometric layout design

· Energy savings calculations

· Product selection assistance

· Certification documentation

For Ordering Information:

· Volume pricing

· Sample evaluation units

· Lead time confirmation

· Shipping logistics

Contact our 1000 watt flood light outdoor 's team: sam@razorlux.com

Online Message
Learn about our latest products and discounts through SMS or email