banner
banner
banner

Led Lights For Soccer Field

Patented Multi-function design, suitable for all working environments.
Rated Power: 90W-1200W
Input Voltage: AC90-305, DC127-431
Color Temperature: 2700K-6500K
Lamp Efficiency: 130LM/W
Beam Angle: 15°, 20°, 30°, 40°, 60°, 120°, 140°x60°.
CRI: Ra>75
IP Grade: IP65/IP67
Bracket: Stainless Steel
Net Weight: 43KG
Warranty: 5 Years
Certificate: CE, RoHS, SAA, C-Tick, UL, DLC, CB, ISO:9001
Send Inquiry Download
  • Product Description

LED Lights For Soccer Field - Professional 1000W Stadium Lighting Solution

Razorlux's LED Lights For Soccer Field deliver broadcast-quality illumination for competitive play. Our 1000W fixtures achieve 130LM/W efficiency with 300-500 lux uniformity (≥0.7) across standard FIFA pitches. Choose from seven beam angles to eliminate glare while meeting Class I-III lighting standards—backed by our 5-year warranty and 200+ lighting patents.

product-1-1

Led Lights For Soccer Field Specifications

product-1-1

FeaturesSpecification
Model NumberRGL2-1200P(ZHGL2-1200P)
Rated Power1200W
Input VoltageAC100-305, DC127-431
Color Temperature2700K-6500K
Lamp Efficiency120LM/W
Lumen Output144000LM
Beam Angle15°, 20°, 30°, 40°, 60°, 120°, 140°x60°
LensTempered Glass
Working Temperature-40° - 60°/ 40F - 140F
CRIRa>75
IP GradeIP67
IK RatingIK10
LED ChipSamsung/Phillip
LED DriverMeanwell
HousingAluminum Alloy
BracketStainless Steel
Net Weight43KG
Warranty5 Years
CertificatesCE, RoHS, SAA, C-Tick, UL, DLC, CB, ISO:9001

product-1-1

Application Scenarios

Professional Sports Stadiums

Meet FIFA Class I standards (500 lux, ≥0.7 uniformity) for televised matches. Our anti-flicker technology (<5% flicker index) ensures crystal-clear slow-motion replays. Over 60 professional venues across Asia-Pacific trust our lighting for championship games.

Training Facilities

Multi-field complexes reduce energy costs by 60% versus metal halide systems. The 30°/60° beam angle combination creates optimal visibility zones—bright enough for skill development, controlled enough to prevent light spillage into neighboring fields.

Community Recreation Centers

Municipal fields benefit from instant-on capability (no 10-minute warm-up delays). Dimming controls (available on request) let you adjust brightness for youth games versus adult leagues, cutting electricity bills by an additional 20-30%.

product-1-1

Educational Institutions

University stadiums appreciate our maintenance-free design—no lamp replacements for 50,000+ hours. Facilities managers report 80% reduction in maintenance calls compared to previous HID systems.

Tournament Venues

Host regional championships with confidence. Our tunable white technology (2700K-6500K) adjusts lighting from warm training ambiance to crisp 5700K broadcast conditions in seconds via DMX control.

product-1-1

Why Choose Razorlux LED Soccer Lighting?

Performance Proven on the Pitch

Since 2015, we've illuminated 200+ soccer venues including national training centers and semi-professional stadiums. Our Led Lights For Soccer Field maintain 92% lumen output after 30,000 operating hours (LM-80 tested).

Patent-Protected Optical System

Asymmetric Precision Optics™ (Patent CN201810xxxxx) directs 95% of light onto the playing surface while keeping beams below 25° from vertical at player eye level—dramatically reducing glare complaints.

Built for Coastal & Harsh Climates

The 316 stainless steel bracket resists salt corrosion in seaside stadiums. IP67 rating means fixtures survive direct water jets during maintenance cleaning. Tested to withstand Category 2 hurricane wind loads (154 km/h).

product-1-1

True Universal Voltage

Works on any power grid (90-305V AC) without transformers—critical for international projects. Automatic voltage detection prevents damage from power surges up to 10kV.

product-1-1

Frequently Asked Questions

Q: How many fixtures do I need for a regulation 105m × 68m field?

A: For FIFA Class II (200 lux, recreational play), typically 12-16 fixtures at 12-14m mounting height. Class I (500 lux, broadcast) requires 20-24 units. We provide free photometric layouts via Dialux simulation—just email your field dimensions.

Q: Will these work with our existing poles?

A: Our universal bracket fits 60-200mm diameter poles. If you have square or irregular structures, we fabricate custom mounts at no additional cost for orders over 10 units.

Q: How do you prevent glare for goalkeepers?

A: Strategic beam angle selection is key. We use narrow 20-30° optics for fixtures directly behind goals, angled at 25° from vertical. This keeps bright zones low while maintaining required lux at ground level.

Q: Can these handle extreme weather?

A: Yes. Operating range is -40°C to +60°C. The IP67-rated housing is pressure-tested to withstand 30 minutes submerged in 1 meter of water (exceeds rain/snow requirements). Wind load rated to 200 km/h.

Contact Us

Email our Led Lights For Soccer Field's team: sam@razorlux.com

Online Message
Learn about our latest products and discounts through SMS or email