banner
banner
banner

led outdoor sport light

Patented Multi-function design, suitable for all working environments.
Rated Power: 1200W
Input Voltage: AC90-305, DC127-431
Color Temperature: 2700K-6500K
Lamp Efficiency: 130LM/W
Beam Angle: 15°, 20°, 30°, 40°, 60°, 120°, 140°x60°.
CRI: Ra>75
IP Grade: IP67
Bracket: Stainless Steel
Net Weight: 15KG
Warranty: 5 Years
Certificate:RMRS CE, RoHS, SAA, C-Tick, UL, DLC, CB, ISO:9001
Send Inquiry Download
  • Product Description

1200W Industrial Led Outdoor Sport Light System

Professional-Grade Illumination for Outdoor Athletic Facilities

Is This Fixture Right for Your led outdoor sport light?

Best Suited For:

· Professional stadiumsrequiring broadcast-quality lighting (500+ lux)

· Municipal sports parkswith 6-10 hour daily operation

· Coastal facilitieswithin 500m of saltwater (C5M corrosion rating)

· Remote locationswith unstable grid voltage (±30% fluctuation tolerance)

· Retrofit projectsreplacing 1500W metal halide systems

Consider Alternatives If:

· Your facility requires <300W per fixture (see our600W model)

· Indoor-only application (our indoor series offers better ROI)

Professional Stadium & Field Lighting Solutions

Product Introduction

Led Outdoor Sport Light Specification

Model

RGL2-1200P

Beam Angle

15° 20° 30°

Stable Flux

(5700K after 1 hour)

144000lm

 

LEDs

1080W

Power

Driver

120W

Consumption

Total

1200W

Replace HID Lamp

2500~3000W

Net Weight

38kg with stainless steel floodlight bracket

Color Temperature

2700-6500K

Color Rendering

≥Ra75 (≥Ra80, ≥Ra90 available on request)

Working Life

≥50000Hrs

Housing Material

Aluminum & Powder coating

Power Supply

Meanwell

IP Class

IP 67

IK Class

IK 10

Insulation Class

Class I

Working Temperature

-40C ~ 60C / -40F ~ 140F

Working Humidity

10% ~ 95%

AC Input

80-315Vac input voltage without additional adapter

Power Factor

≥0.98

Warranty

LED Module

5 year

 

 

 

 

Driver

5 year

 

Housing

10 year

product-1-1

Application-Specific Guidance

1. Stadium Perimeter Lighting

Suggested Configuration:

· Mounting stature: 20-30 meters

· Bar point: 15° or 25° (narrow throw)

· Format: 6-8 installations per standard football pitch

· Target illuminance: 500 lux (preparing) / 750 lux (competition)

Photometric Simulation:Upload Your Location Planfor free analysis

2. Tennis Court Lighting

Recommended Configuration:

· Mounting stature: 8-12 meters

· Pillar point: 40° or 60° (medium spread)

· Format: 4 installations per court (2 per side)

· Target illuminance: 300 lux (recreational) / 500 lux (competition)

led outdoor lights quality control process

3. Multi-Purpose Athletic Fields

Recommended Configuration:

· Color temperature: 4000K (neutral white for mixed sports)

· Dimming: 0-10V or DALI for multi-mode operation

· Spill light control: 140°x60° asymmetric optics for adjacent area protection

Dimming Profiles:Download Pre-Configured Settings

LED outdoor lights Packaging and Transportation

Product Features (Ranked by Customer Priority)

Rated: Wide Voltage Tolerance

What This Means for You:

If your facility experiences voltage sags during high-demand periods (common in industrial areas or developing regions), this led outdoor sport light maintains consistent brightness between 90V-305V AC. Internal power factor correction ensures stable operation.

Technical Detail:Active PFC with THD <15% tested per IEEE 519

Rated: Tool-Free Beam Adjustment

What This Means for You:

After installation, you can adjust the aiming angle ±15° without loosening mounting bolts. This eliminates cherry picker rental costs when fine-tuning illumination patterns.

Rated: Modular Driver Design

What This Means for You:

If the driver fails (rare but possible after 7-10 years), any electrician can replace it in 15 minutes without dismounting the fixture.Parts Guarantee:Replacement drivers available through 2040 (documented commitment)

led outdoor sport light certification

Frequently Asked Questions

Installation & Compatibility

Q: Can I introduce this myself, or do I require a authorized electrician?

A:Always utilize a authorized electrician.This is a high-voltage (up to 305V) lasting establishment requiring compliance with nearby electrical codes (NEC Article 410 in USA, BS 7671 in UK). DIY establishment voids guarantee and makes security hazards.

Q: Will this work with my existing photocell or clock system?

A: Yes, if your control framework gives clean AC control exchanging. For progressed highlights (dimming, scheduling), indicate our DALI driver alternative at checkout.

Performance & Specifications

Q: How shinning is 156,000 lumens in commonsense terms?

A: At 20 meters mounting tallness with 25° bar point, you'll accomplish around 450-500 lux at ground level (sufficient for training/recreational sports). For reference:

  • 200 lux = Least for casual play
  • 500 lux = Suggested for training
  • 750+ lux = Broadcast/professional competition

Q: What's the genuine life expectancy in hours?

A:54,000 hours to L80(maintains 80% of introductory brightness), based on IES LM-80 testing at 55°C surrounding temperature. In normal 6-hour/day operation:

  • L80: 24.6 years
  • L70 (70% brightness): ~70,000 hours = 31.9 years

Caveat:Lifespan decreases in extraordinary warm. At 50°C surrounding, anticipate L80 around 42,000 hours.

Next Steps

Need Expert Guidance?

Talk to Our led outdoor sport light designers:

North America:

Sam Chen, Senior Sales Engineer

sam@razorlux.com

Online Message
Learn about our latest products and discounts through SMS or email