banner
banner
banner

outdoor hockey rink lighting

Patented Multi-function design, suitable for all working environments.
Rated Power: 400W
Input Voltage: AC90-305, DC127-431
Color Temperature: 2700K-6500K
Lamp Efficiency: 130LM/W
Beam Angle: 15°, 20°, 30°, 40°, 60°, 120°, 140°x60°.
CRI: Ra>75
IP Grade: IP67
Bracket: Stainless Steel
Net Weight: 22KG
Warranty: 5 Years
Certificate:RMRS CE, RoHS, SAA, C-Tick, UL, DLC, CB, ISO:9001
Send Inquiry Download
  • Product Description

Professional Outdoor Hockey Rink Lighting | Cold-Weather LED Solutions

Playing hockey shouldn't cruel engaging unsafe ice glare or managing with lights that come up short when temperatures drop. That's why over 150 hockey offices over North America believe Razorlux Led outdoor hockey rink lighting to keep their arenas shinning, secure, and operational—even at -40°C.

The difference?Specialized optics that kill glare, military-grade lodgings that survive puck impacts, and lighting frameworks built particularly for ice sports (not fair adjusted from stopping parcel fixtures).

>Quick Win:Facilities exchanging to our Led frameworks report 60-75% lower vitality costs and zero light substitutions in the to begin with 5 years.

product-1-1

    product-1-1

    Outdoor Hockey Rink Lighting Specification

    Model

    RGL2-400P

    Beam Angle

    15° 20° 30°

    Stable Flux

    (5700K after 1 hour)

    48000lm

    Dimension (mm)

    466*388*487

     

    LEDs

    360W

    Power

    Driver

    40W

    Consumption

    Total

    400W

    Replace HID Lamp

    800~1000W

    Net Weight

    19kg with stainless steel floodlight bracket

    Color Temperature

    2700-6500K

    Color Rendering

    ≥Ra75 (≥Ra80, ≥Ra90 available on request)

    Working Life

    ≥50000Hrs

    Housing Material

    Aluminum & Powder coating

    Power Supply

    Meanwell

    IP Class

     IP 67

    IK Class

    IK 10

    Insulation Class

    Class I

    Working Temperature

    -40C ~ 60C / -40F ~ 140F

    Working Humidity

    10% ~ 95%

    AC Input

    110-480Vac input voltage without additional adapter

    DC Input

    100 ~ 400Vdc, 500Vdc ~ 800Vdc

    THD

    <10%

    Power Factor

    ≥0.98

    Warranty

    LED Module

    5 year

     

    Driver

    5 year

     

    Housing

    10 year

    product-1-1

    The 3 Critical Challenges of Hockey Rink Lighting (And How We Solve Them)

    Challenge 1: Ice Glare Blinds Players

    When standard floodlights hit intelligent ice, they make "ice blindness"—a unsafe glare that darkens the puck at basic moments.
    Our Solution:

    Outdoor hockey rink lighting asymmetric bar points (protected plan) coordinate light at exact points to minimize reflection. Players see the puck clearly, indeed amid high-speed plays over 100 mph.

    Real Result:Riverdale Community Arena diminished player complaints by 90% after installation

    Technical Edge:5000K color temperature optimizes puck-to-ice contrast

    product-1-1

    Challenge 2: Extreme Cold Kills Standard Fixtures

    Conventional lights come up short when temperatures dive. Seals split, drivers breakdown, and your arena goes dull mid-game.
    Our Solution:

    Every component is warm shock-tested through 100+ freeze-thaw cycles (-40°C to +50°C). Cold-start drivers provide full brightness instantly—no warm-up time, indeed in brutal cold.

    • Proven Durability:50,000+ hour life expectancy (that's 15+ a long time of ordinary use)
    • Impact Resistance:IK10-rated covers survive coordinate puck hits without cracking

    Challenge 3: Energy Costs Spiral Out of Control

    Traditional metal halide frameworks are vitality vampires, creating over the top warm (which dissolves your ice) whereas driving up power bills.
    Our Solution:

    130 lumens-per-watt proficiency cuts vitality utilize by 60-75% compared to ancient frameworks. Less warm implies superior ice quality and lower cooling costs.

    product-1-1

    product-1-1

    Frequently Asked Questions

    "Will these lights really work at -40°C?"

    Yes. We've installed systems in Yukon, Alaska, and northern Canada. Our cold-start drivers are tested to -40°C and deliver full brightness immediately—no waiting for warm-up.

    "How do you prevent light pollution in residential areas?"

    Precision back-light shields and cutoff angles keep light contained within the rink perimeter. We meet IDA Dark Sky compliance standards.

    "What's the real lifespan?"

    Our fixtures maintain 70% brightness after 50,000 hours (15 years of typical use). The 5-year warranty covers any issues, but failures are rare—our return rate is under 0.3%.

    "Can these handle puck impacts?"

    Absolutely. IK10-rated polycarbonate covers are tested with 6-ounce pucks at regulation speeds. No cracks, no shattering.

    "Do you help with installation planning?"

    Yes. We provide free photometric analysis, mounting layouts, and technical support during installation. Many customers use our IES files with their local contractors.

    product-1-1

    Get Your Custom Lighting Plan (Free)

    Here's what you'll receive:

    ✓ Photometric analysis for your rink dimensions

    ✓ Lux distribution maps showing uniformity

    ✓ Energy savings calculation

    ✓ Mounting specifications and layout

    ✓ Project quote with ROI timeline

    No obligation. No sales pressure. Just expert guidance.

    Contact our outdoor hockey rink lighting's team:sam@razorlux.com

    Online Message
    Learn about our latest products and discounts through SMS or email