baseball stadium lights
Rated Power: 1200W
Input Voltage: AC90-305, DC127-431
Color Temperature: 2700K-6500K
Lamp Efficiency: 130LM/W
Beam Angle: 15°, 20°, 30°, 40°, 60°, 120°, 140°x60°.
CRI: Ra>75
IP Grade: IP67
Bracket: Stainless Steel
Net Weight: 32KG
Warranty: 5 Years
Certificate:RMRS CE, RoHS, SAA, C-Tick, UL, DLC, CB, ISO:9001
- Product Description
1200W Professional Baseball Stadium Lights | Razorlux
Illuminate Your Field Like the Pros Do
When Riverside Community College upgraded their baseball stadium lights in 2023, they faced a common challenge: required constant bulb replacements. After switching to our 1200W LED system, they haven't replaced a single fixture in 18 months.
Is your stadium facing similar challenges?Our enterprise-grade LED floodlights solve three critical problems:
✓Eliminate ongoing maintenance costs- 50,000+ hour lifespan means 20+ years of operation
✓Cut energy consumption by 60%- 130LM/W efficiency vs. 40-50LM/W for metal halide
✓Improve game visibility- Instant-on, flicker-free lighting with broadcast-quality CRI >75


Baseball Stadium Lights Specification
Model | RGL2-1200P | |
Beam Angle | 15° 20° 30° | |
Stable Flux (5700K after 1 hour) | 144000lm | |
| LEDs | 1080W |
Power | Driver | 120W |
Consumption | Total | 1200W |
Replace HID Lamp | 2500~3000W | |
Net Weight | 38kg with stainless steel floodlight bracket | |
Color Temperature | 2700-6500K | |
Color Rendering | ≥Ra75 (≥Ra80, ≥Ra90 available on request) | |
Working Life | ≥50000Hrs | |
Housing Material | Aluminum & Powder coating | |
Power Supply | Meanwell | |
IP Class | IP 67 | |
IK Class | IK 10 | |
Insulation Class | Class I | |
Working Temperature | -40C ~ 60C / -40F ~ 140F | |
Working Humidity | 10% ~ 95% | |
AC Input | 80-315Vac input voltage without additional adapter | |
Power Factor | ≥0.98 | |
Warranty | LED Module | 5 year |
|
|
|
| Driver | 5 year |
| Housing | 10 year |

Why Stadium Managers Choose Razorlux
1. Proven Performance in Real Conditions
Our lights currently illuminate 200+ baseball fields across North America, including:
· AAA Minor League stadiumsin humid Southern climates
· University athletic complexesin harsh Midwest winters
· Coastal municipal parksin salt-spray environments
2. Engineering That Makes a Difference
Why our lights last longer:
· Proprietary thermal management system (Patent #CN201810567) keeps LED junction temperature 20°C cooler than industry average
· Marine-grade 316 stainless steel brackets resist corrosion 5x better than standard 304 steel
· We manufacture our own LED drivers (not outsourced) - this integration eliminates the #1 failure point in stadium lights
Our baseball stadium lights's team includes:
· 12 lighting engineers with sports venue specialization
· Collaboration with Beijing Institute of Technology's Optical Engineering department
· ISO 9001:2015 certified manufacturing since 2001

3. Flexible Power = Future-Proof Investment
Dual-voltage design (AC/DC) means:
· Works with existing stadium electrical infrastructure
· Compatible with backup generators and battery systems
· Easy integration when adding solar power later
· No expensive transformer upgrades needed
4. Light Quality Athletes Notice
High CRI (>75) delivers:
· White baseballs stay white (not yellow/gray like old HID lights)
· Accurate grass and line visibility for umpires
· Reduced eye strain for players tracking fly balls
· HD broadcast-ready illumination for media coverage
Beam angle options solve specific problems:
· 25° spots: Infield precision (pitcher's mound, bases)
· 60° floods: Outfield coverage
· 140°x60° asymmetric: Spectator areas without field glare

Common Applications
Professional & College Stadiums
Lighting Class III-IV compliance- Our design team provides photometric analysis showing compliance with NCAA and MLB lighting standards. Typical layouts use 6-12 fixtures on 4-6 poles.
High School & Community Fields
Budget-conscious performance- Achieve Class II recreational lighting with 6-8 fixtures. Qualify for utility rebates (DLC listed) that cover 20-40% of project costs.
Multi-Use Complexes
One system, multiple sports- Adjustable beam angles work for baseball, softball, soccer, and football. Optional dimming controls (0-10V/DALI) let you scale brightness for practices vs. games.
Retrofit Projects
Works with existing poles- Our adjustable brackets mount to 3"-8" diameter poles. Installation typically takes 2-3 days for an 8-light system.

Why Buy Direct from Manufacturer?
Distributor markups- competitors add 30-50%
Generic support- resellers read from manual
Engineering support- talk to people who designed the product
Stock limitations- wait for distributor inventory
Custom configurations- beam angles, voltages, controls made to order

Frequently Asked Questions
Q: How do I know how many lights I need?
A: We provide free lighting design using AGI32 software (industry standard). Send us your field dimensions, and we'll deliver:
· 3D illumination maps showing foot-candle levels
· Uniformity calculations (max/min ratios)
· Lighting class compliance verification
· Pole layout recommendations
Q: What happens if a light fails?
A: Our 5-year warranty covers:
· Free replacement units (shipped within 48 hours)
· Labor reimbursement for certified installers
· Advance replacement program - we send new unit before you return defective one
Historical failure rate: <0.3% in first 5 years
Q: Can I dim these lights for practice sessions?
A: Yes - available options:
· 0-10V analog dimming(10-100% range) - most common
· DALI digital control- integrate with building automation
· DMX protocol- for entertainment/event lighting effects
Dimming extends lifespan and saves energy during practices.
Q: How long does installation take?
A: Typical timeline for 8-light system:
· Day 1: Mount fixtures, run wiring
· Day 2: Electrical connections, aiming
· Day 3: Final adjustments, inspection
We provide detailed installation manuals and remote support via video call.
Q: Do you install, or do I need to hire someone?
A: We work three ways:
1. Ship to your electrician- we support them during install
2. Recommend certified installersin your area (50+ nationwide)
Q: What if my city requires a specific color temperature?
A: We stock 4000K, 5000K, and 5700K as standard. Custom temperatures (2700K-6500K) available with 2-week lead time. Most municipalities require 4000K-5000K to minimize light pollution.
Get Your Custom Lighting Plan
Email Project Details
Send field dimensions and photos to our baseball stadium lights's team :sam@razorlux.com
VIEW MOREoutdoor ice rink lights
VIEW MOREoutdoor riding arena lights
VIEW MOREoutdoor horse arena lights
VIEW MOREmarine flood lights
VIEW MOREConstruction Emergency Led Explosion Proof Light 80w 8000lm Paint Booth Light
VIEW MORE6000K 270w Dimmable Outdoor Light 60 Degree Flood Light For Basketball Court
VIEW MORE180w Dimmable Led Flood Light 60 Beam Degree Super Bright Led Light 120lm/W
VIEW MOREIP66 Building 500W Dimmable Led Flood Light 10 Degrees Angle Wall Washer Spotlight

_1750326878398.png)




