led arena flood lights
Rated Power: 1000W
Input Voltage: AC90-305, DC127-431
Color Temperature: 2700K-6500K
Lamp Efficiency: 130LM/W
Beam Angle: 15°, 20°, 30°, 40°, 60°, 120°, 140°x60°.
CRI: Ra>75
IP Grade: IP67
Bracket: Stainless Steel
Net Weight: 32KG
Warranty: 5 Years
Certificate:RMRS CE, RoHS, SAA, C-Tick, UL, DLC, CB, ISO:9001
- Product Description
1000W LED Arena Flood Lights | Stadium-Grade Lighting for Professional Venues
What makes our led arena flood lights different?After testing 1,247+ installations across 34 countries since 2006, we've engineered flood lights that solve the three biggest complaints about stadium lighting: uneven coverage, high failure rates in harsh weather, and excessive energy costs.

LED Arena Flood Lights Introduction
Model | RGL2-1000P | |
Beam Angle | 15° 20° 30° | |
Stable Flux (5700K after 1 hour) | 120000lm | |
| LEDs | 900W |
Power | Driver | 100W |
Consumption | Total | 1000W |
Replace HID Lamp | 2200~2500W | |
Net Weight | 38kg with stainless steel floodlight bracket | |
Color Temperature | 2700-6500K | |
Color Rendering | ≥Ra75 (≥Ra80, ≥Ra90 available on request) | |
Working Life | ≥50000Hrs | |
Housing Material | Aluminum & Powder coating | |
Power Supply | Meanwell | |
IP Class | IP 67 | |
IK Class | IK 10 | |
Insulation Class | Class I | |
Working Temperature | -40C ~ 60C / -40F ~ 140F | |
Working Humidity | 10% ~ 95% | |
AC Input | 80-315Vac input voltage without additional adapter | |
Power Factor | ≥0.98 | |
Warranty | LED Module | 5 year |
| Driver | 5 year |
| Housing | 10 year |

Why Our Lights Last Longer (Engineering Details)
1. Thermal Management System
The issue with most Led installations: Warm murders LEDs. Ineffectively planned heatsinks cause 80% of untimely failures.
Our solution(Patent #ZL201810234567.8):
·Graphene-enhanced aluminum warm sink (32% better thermal conductivity)
·Separated driver compartment (driver runs 15°C cooler)
·CFD-optimized blade plan (verified in 1000-hour thermal cycle testing)
Result: Intersection temperature remains underneath 85°C indeed at 45°C surrounding (industry normal: 95-110°C)
2. Power Supply Reliability
Our foundation: We fabricated mechanical control supplies 1998-2006 some time recently entering Led lighting. This isn't outsourced—we plan each driver.
Features you won't find elsewhere:
· Active PFC (>0.95 power factor)
· 10kV surge protection (tested to IEC 61000-4-5)
· Conformal coated boards (moisture protection in humid environments)
Failure data: 0.31% annual failure rate across 124,000 installed units (2020-2024 tracking)

3. Optical Precision
Standard practice: Most manufacturers use generic reflectors with ±15% variation in beam pattern.
Our process:
· Custom-tooled reflectors for each beam angle
· Computer-modeled lens arrays (TracePro simulation)
· Individual testing with goniophotometer (we reject 2.3% that fall outside ±5% spec)
Result: Uniform illumination—less than 10% variance across the lit area

Complete Support Package
What's included of led arena flood lights:
Pre-Sale: Free photometric simulation (48-hour turnaround)
Design: Custom mounting drawings, electrical schematics
Installation: Video guides, remote tech support via WhatsApp/WeChat
Commissioning: Aiming assistance (we can review photos remotely)
Warranty: 5 years comprehensive (not pro-rated)
Spares: 3% spare units included for large orders (>200 units)


FAQ (Based on 500+ Customer Questions)
Installation & Technical
Q: What's the actual weight with Packaging?
A: 18kg including wood crate. One person can handle installation, but we recommend two for safety at heights.
Q: Can I use standard mounting brackets?
A: No. We include custom brackets designed for the weight distribution. Using generic brackets voids the warranty and creates safety risks.
Q: Do you provide aiming angles?
A: Yes. Our photometric design service includes specific aiming angles for each fixture location (elevation and azimuth).
Q: What gauge wire do I need?
A: For 1000W at 220V: minimum 3x2.5mm² up to 50m run, 3x4mm² for 50-100m. See detailed electrical guide in documentation.
Dimming & Control
Q: Can I integrate with building management systems?
A: Yes via DALI. We've successfully integrated with Siemens, Honeywell, and Johnson Controls BMS platforms.
Q: Response time when dimming?
A: Instantaneous (no flicker). Unlike HID, you can dim mid-event without restrike delays.
Warranty & Service
Q: What actually fails in LED fixtures?
A: In our experience (124k units tracked): 67% driver failures, 28% LED module failures, 5% mechanical/seal issues.
Q: Do you have US-based inventory?
A: For standard configurations, yes (Los Angeles warehouse, ~500 units stock). Custom specs ship from China (15-20 days production + 25-30 days ocean freight).

Get Started
Custom Design Service (For Complex Projects)
Best for stadiums, large facilities
We'll provide(within 48 hours):
· Photometric simulation (DIALux/AGi32)
· Fixture layout drawing
· Detailed specification
· Budget pricing
What we need from you:
· CAD file or dimensioned drawing
· Mounting height
· Light level requirements
· Application type
Conatct our led arena flood lights team:sam@razorlux.com
VIEW MOREMarine Spot Flood Light
VIEW MOREMarine Boat Led Flood Lights
VIEW MORECommercial Marine Flood Lights
VIEW MOREIndustrial Marine Flood Lights
VIEW MOREWaterproof Marine High Intensity Led Flood Light
VIEW MOREBest Marine Spotlights For Boats
VIEW MOREBest Marine Led Flood Lights
VIEW MOREBoat Deck Flood Lights

_1750326878398.png)