led flood light projector

Patented Multi-function design, suitable for all working environments.
Rated Power: 180W
Input Voltage: AC90-305, DC127-431
Color Temperature: 2700K-6500K
Lamp Efficiency: 130LM/W
Beam Angle: 15°, 20°, 30°, 40°, 60°, 120°, 140°x60°.
CRI: Ra>75
IP Grade: IP67
Bracket: Stainless Steel
Net Weight: 15KG
Warranty: 5 Years
Certificate:RMRS CE, RoHS, SAA, C-Tick, UL, DLC, CB, ISO:9001
Send Inquiry Download
  • Product Description

Led Flood Light Projector

Your choice of system may effect everything from player safety to energy expenses if your football field needs consistent illumination for night games or training. Razorlux 1000W led flood light projector is a professional quality illumination for sports venues. They provide broadcast-quality brightness and weather-resistant durability with a lifespan of over a decade.

LED Flood Light Projector Overview

Led Flood Light Projector Specifications

FeatureSpecification
Model NumberRGL-180P
Rated Power180W
Input VoltageAC100-305, DC127-431
Color Temperature2700K-6500K
Lamp Efficiency120LM/W
Lumen Output21600LM
Beam Angle20°, 40°, 60°, 120°, 140°x60°
LensTempered Glass
Working Temperature-40° - 60°/ 40F - 140F
CRIRa>75
IP GradeIP67
IK RatingIK10
LED ChipSamsung/Cree
LED DriverMeanwell
HousingAluminum Alloy
BracketStainless Steel 316
Net Weight13KG
Warranty5 Years
CertificatesRMRS, CE, RoHS, SAA, C-Tick, UL, DLC, CB, ISO:9001, Salt Spray Testing, C4M
More Available Powers90W,120W, 150W, 180W, 210W, 270W, 200W, 300W, 400W, 500W, 600W, 800W, 1000W, 1200W

product-1-1

Why Football Fields Choose Razorlux Lighting

No More Flickering During Video Recording

Modern cellphones and broadcast cameras see flicker invisible to the eye. Our high frequency LED drivers remove this strobing effect so slow motion replays seem smooth whether you are streaming on YouTube or broadcasting on national television.” Parents shooting youth sports and professional videographers receive the same clear footage.

A color rendering index over 75 implies team jerseys, field markings and skin tones seem true to life, which is crucial when sponsors are reviewing broadcast video or coaches are reviewing game film.

IP67 and IK10 Testing

Designed for Harsh Weather Conditions

Rain or coastal humidity, football season never ends. The C5M grade anti-corrosion coating withstands 48-72 hours salt spray testing and each led flood light projector is sealed against water jets and dust entry to IP65/IP67. Standard fixtures deteriorate faster with rust within 5 km of coastlines—our marine-grade design eliminates this.

316 stainless steel mounting brackets prevent oxidation even in tropical conditions with 90%+ humidity. The aerodynamic housing design lowers wind load stress in storms, retaining structural integrity at mounting heights up to 35 meters.

Reduce Light Pollution Complaints

Excessive brightness is a frequent source of complaints from neighbors of municipal fields. Our asymmetric optical design puts the light just where it’s needed, on the playing surface, with minimum spill beyond the field borders. Adjustable beam angles (60°/120°/140°x60°) enable you modify coverage for pole height and field size.

Accuracy is important for community relations and regulatory compliance. Dark Sky compliance is now a requirement for new sports lighting installations in many countries and our lights exceed those standards without sacrificing the quality of field illumination.

beam angle options

Common Applications

Professional and Semi-Professional Stadiums

For venues hosting televised matches, the TLCI (Television Lighting Consistency Index) rating must be above 90 to ensure proper color reproduction. Our lights meet this standard, and also offer DMX512 and RDM control protocols for coordinated lighting effects during pre-game entertainment.

The broad input voltage range (AC 80-315V) makes it ideal for generator powered temporary facilities or locations with unstable grid supply such as those in developing countries or distant training centers.

Multi-Sport Training Facilities 
Adjustable color temperature (2700K-6500K) provides operators the ability to vary between warm tones for evening leisure usage and daylight balanced output for high performance training. No separate systems for football, soccer or rugby, field activities use the same lighting infrastructure.

Infransture and heavy-duty marine application model used are RGL-1000P

Quality Assurance Process

Each fixture undergoes photometric testing in our integrating sphere laboratory to verify actual lumen output matches IES file specifications. Thermal stress testing monitors LED junction temperatures during 72-hour continuous operation cycles—we reject any batch where temperatures exceed 85°C.

Electrical testing confirms Total Harmonic Distortion stays below 15% and power factor exceeds 0.95 across the full voltage range. These parameters ensure compatibility with sensitive electrical environments and maximize component lifespan.

Our Xi'an facility holds ISO 9001 certification (maintained since 2001) and operates an LED Lighting Engineering Laboratory authorized by China's National Development and Reform Commission.

stadium light used model RGL-180A and RGL-400A

commercial application used model RGL-150A

    packing details for RGL-180P

    transaction feedback

    Frequently Asked Questions

    What light level should I target with different uses?

    Training sessions usually demand an average light of 200-300 lux. “You need between 300 and 500 lux for competitive amateur matches.” Professional televised games require 500-750 lux with uniformity ratios (U1) greater than 0.6. We provide free lighting estimations depending on your pole height, field size and use needs.

    How can I avoid flicker in video recordings? 

    Our LED drivers operate above 20 kHz switching frequency, well beyond the detection threshold of cameras recording at 24-240 fps.  This eliminates banding artifacts in slow-motion replays and smartphone videos.

    Can these lights be used for coastal or high humidity areas?

    Yes.  The C5M anti-corrosion coating and IP67-rated sealing guard against salt spray and moisture infiltration. For facilities within 1 km of coasts, select 316 stainless steel brackets (standard on our 1000W model) in lieu of aluminum to maximize corrosion resistance.

    What is a good maintenance schedule?

    Lower maintenance than HID bulbs. We propose yearly checking of bracket tightness and cleaning of optical lenses. With a L70 lifetime reaching 50,000 hours, anticipate 10-15 years before light output falls to 70% of original levels.

    Do you provide lighting layout design services?

    Yes. Our engineering team offers complimentary lighting simulations using Dialux or AGi32 software. Provide your field dimensions, mounting heights, and target lux levels—we'll generate a photometric report showing fixture placement, aiming angles, and predicted uniformity.

    How does dimming control work?

    Fixtures support 0-10V analog dimming and DALI digital protocols. You can integrate these with building management systems, motion sensors, or manual wall controls. Dimming to 30% during practice sessions extends lifespan while reducing energy consumption.

    RMRS, UL, CE, RoHS, TUV, SAA, C-Tick Certification

    Contact Us

    Contact our led flood light projector's team: sam@razorlux.com

    Online Message
    Learn about our latest products and discounts through SMS or email