high output led floodlight
Rated Power: 500W
Input Voltage: AC90-305, DC127-431
Color Temperature: 2700K-6500K
Lamp Efficiency: 130LM/W
Beam Angle: 15°, 20°, 30°, 40°, 60°, 120°, 140°x60°.
CRI: Ra>75
IP Grade: IP67
Bracket: Stainless Steel
Net Weight: 23KG
Warranty: 5 Years
Certificate:RMRS CE, RoHS, SAA, C-Tick, UL, DLC, CB, ISO:9001
- Product Description
High Output Led Floodlight | 65,000 Lumens High Output
This high output led floodlight delivers65,000 lumensof dependable light for ports, seaward stages, mining destinations, and expansive fabricating offices. Since 2006, we've made a difference operations supervisors decrease vitality costs whereas moving forward work environment safety.
Key Execution Metrics:
- 130 LM/W efficiency– among the most elevated in mechanical lighting
- 50,000+ hour lifespan– 5-7 a long time of nonstop operation
- IP67 waterproof rating– demonstrated in 1,000+ hour salt shower tests
- Universal voltage (AC90-305V / DC127-431V)– works with unsteady control grids

High Output Led Floodlight Specification
Model | RGL2-500A | |
Beam Angle | 40° 60° 120° 140° | |
Stable Flux (5700K after 1 hour) | 65000lm | |
Dimension (mm) | 468*388*367 | |
| LEDs | 450W |
Power | Driver | 50W |
Consumption | Total | 500W |
Replace HID Lamp | 1000~1200W | |
Net Weight | 15kg with stainless steel floodlight bracket | |
Color Temperature | 2700-6500K | |
Color Rendering | ≥Ra75 (≥Ra80, ≥Ra90 available on request) | |
Working Life | ≥50000Hrs | |
Housing Material | Aluminum & Powder coating | |
Power Supply | Meanwell | |
IP Class | IP 67 | |
IK Class | IK 10 | |
Insulation Class | Class I | |
Working Temperature | -40C ~ 60C / -40F ~ 140F | |
Working Humidity | 10% ~ 95% | |
AC Input | 110-480Vac input voltage without additional adapter | |
DC Input | 100 ~ 400Vdc, 500Vdc ~ 800Vdc | |
THD | <10% | |
Power Factor | ≥0.98 | |
Warranty | LED Module | 5 years |
| Driver | 5 years |
| Housing | 10 years |

Application Examples
Port & Container Terminals
Challenge:24/7 cargo dealing with requires shadow-free lighting over 10-20 section of land yards
Solution:Wide pillar (120°-140°) setup gives uniform scope from high-mast towers
Result:Shanghai Yangshan Port diminished vitality utilization by 68% after supplanting 1500W Metal Halide fixtures
Offshore Oil Platforms
Challenge:Salt splash, tall winds, and temperature swings (-40°C to +50°C)
Challenge:Limited support access
Solution:RMRS-certified marine-grade development + 50,000 hour lifespan
Result:5+ a long time operation without disappointments on North Ocean platforms

Open-Pit Mining
Challenge:Dust, vibration, and persistent operation
Solution:IP67 tidy assurance + shock-resistant 15KG housing
Beam Selection:40°-60° medium pillar for unearthing faces, 15°-30° contract pillar for pull roads
High-Bay Warehouses
Challenge:30-50 foot ceiling statures, instant-on required for movement sensor integration
Solution:Zero warm-up time + tall CRI for standardized identification filtering

What Makes This Different
1. Thermal Management = Longer Lifespan
Most LED failures come from heat damage. Ourpatented heat sink design(CN Patent No. 201X...) keeps LED junction temperature 15-20°C cooler than competitor products.
How we verify this:Every production batch undergoes thermal imaging at full power. We publish thermal test reports with each bulk order of high output led floodlight.
2. Universal Voltage Saves Installation Costs
Standard fixtures need external transformers for:
· Solar power systems (DC input)
· Generator power (fluctuating voltage)
· International projects (110V vs. 220V vs. 380V grids)
Our built-in driverhandles AC 90-305V and DC 127-431V directly. One SKU works globally.
3. Seven Beam Angles (Most Brands Offer 2-3)
Beam Angle | Best For | Mounting Height |
15° | High-mast towers, long-distance | 20-30 meters |
20°-30° | Parking lots, roadways | 15-20 meters |
40°-60° | General area lighting | 10-15 meters |
120° | Wide coverage, low ceilings | 6-10 meters |
140°x60° | Rectangular areas, sports fields | 10-15 meters |
Free service:Send us your site dimensions and we'll calculate optimal beam angle + placement.

4. Testing Beyond Industry Standards
Standard IP67 testing: 30 minutes at 1-meter water depth
Our testing:2 hours at 1.5-meter depth + 1,000 hours salt spray (5x industry standard)
Why?Because offshore and coastal environments are harsher than laboratory conditions.

Common Questions
Q: Which beam angle do I need?
A: Send us three details: mounting height, area dimensions, and current light type. We'll recommend the optimal angle within 24 hours.
Q: Can I dim these lights?
A: Yes, optional 0-10V or DALI dimming available . Dimming to 30% extends lifespan to 70,000+ hours.
Q: What if my voltage fluctuates heavily?
A: The driver handles ±20% fluctuation without damage. For extreme cases (±30%), we offer an upgraded surge protection module tested to 20kV.
Q: Do you ship internationally?
A: Yes. We ship via DHL/FedEx (samples) or ocean freight (bulk). Typical delivery: 7-10 days (US), 10-15 days (Europe), 15-20 days (other regions).
Contact Information
For Technical Questions:
Contact our high output led floodlight's team:sam@razorlux.com

_1750326878398.png)