banner
banner
banner

led high power flood light

Patented Multi-function design, suitable for all working environments.
Rated Power: 1200W
Input Voltage: AC90-305, DC127-431
Color Temperature: 2700K-6500K
Lamp Efficiency: 130LM/W
Beam Angle: 15°, 20°, 30°, 40°, 60°, 120°, 140°x60°.
CRI: Ra>75
IP Grade: IP67
Bracket: Stainless Steel
Net Weight: 42KG
Warranty: 5 Years
Certificate:RMRS CE, RoHS, SAA, C-Tick, UL, DLC, CB, ISO:9001
Send Inquiry Download
  • Product Description

1200W Led High Power Flood Light for Heavy Industry | RMRS Marine CertifiedQuick Specifications

Power:1200W led high power flood light→Output:156,000 Lumens →Replaces:2000W Metal Halide

Voltage Range:AC 90-305V / DC 127-431V (No Transformer Needed)

Protection:IP67 Waterproof + 10KV Surge Protection

Lifespan:50,000 Hours (11+ A long time) |Warranty:5 Years

Energy Savings:40-50% less control vs. conventional HID

Marine Grade:RMRS certified for offshore/coastal use

Custom Options:7 bar points (15°-140°×60°) for 10-40m mounting heights

high-power-flood-light-appearance

Led High Power Flood Light Specifications

Model

RGL2-1200P

Beam Angle

15° 20° 30°

Stable Flux

(5700K after 1 hour)

144000lm

 

LEDs

1080W

Power

Driver

120W

Consumption

Total

1200W

Replace HID Lamp

2500~3000W

Net Weight

38kg with stainless steel floodlight bracket

Color Temperature

2700-6500K

Color Rendering

≥Ra75 (≥Ra80, ≥Ra90 available on request)

Working Life

≥50000Hrs

Housing Material

Aluminum & Powder coating

Power Supply

Meanwell

IP Class

 IP 67

IK Class

IK 10

Insulation Class

Class I

Working Temperature

-40C ~ 60C / -40F ~ 140F

Working Humidity

10% ~ 95%

AC Input

80-315Vac input voltage without additional adapter

Power Factor

≥0.98

Warranty

LED Module

5 year

 

 

 

 

Driver

5 year

 

Housing

10 year

high-power-flood-light-technical-details

Why Upgrade to This LED Solution?

Replace Outdated Metal Halide Systems

  • Immediate taken a toll cut:480W spared per installation 
  • Eliminate relamping:50,000-hour life expectancy = 5x longer than HID
  • Instant operation:No 15-minute warm-up delays

high-power-flood-light-manufacturing-process

Built for Harsh Environments

Installed at:

  • Port of Qingdao- Holder terminal lighting (800+ units, 3 a long time zero failures)
  • BHP Coal Mine- Underground roadway lighting (-30°C to +45°C operation)
  • Shanghai Shipyard- Salt shower zone (C5M coating passed 3000-hour test)

marine-vessel-lighting

Choose the Right Beam Angle

Mounting Height

Recommended Angle

Typical Use

30-40 meters

15° / 20°

Stadium towers, high-bay warehouses

15-25 meters

30° / 40°

Factory floors, rail yards

10-15 meters

60°

Loading docks, parking lots

5-10 meters

120° / 140°×60°

Perimeter walls, walkways

port-and-mining-site-crane-lighting

Application Examples

Ports & Shipyards

· Challenge:Salt corrosion + 24/7 operation + cranes blocking light

· Solution:RMRS-certified fixtures with 40° beams at 25m height

· Result:156,000 lumens illuminate 900 m² per fixture (verified by dialux simulation)

Mining Operations

· Challenge:Explosive dust + vibration + unstable DC power (127V-220V fluctuation)

· Solution:IP67 + wide voltage driver + shockproof mounting

· Result:Operational in -30°C Siberian coal mines (client: Mechel Group)

high-power-flood-light-quanlity-control-qa-testing

Manufacturing Plants

· Challenge:35m ceiling height + heat from furnaces + strict color accuracy for QC

· Solution:20° narrow beam + CRI >80 option + 50°C ambient rating

· Result:Replaced 400W HPS lamps in steel mill (60% energy reduction)

high-power-flood-light-packing-methods

 Verify Our Claims: Test Data

We don't just list specs of led high power flood light– we prove them:

Thermal Performance Test

· Ambient Temp:45°C (113°F) chamber

· Junction Temp after 48h:68°C (target: <70°C)

Salt Spray Corrosion Test

· Standard:IEC 60068-2-52 (C5M grade)

· Duration:3,000 hours continuous spray

Lumen Maintenance Test

· Duration:6,000 hours accelerated aging (equals 30,000 real hours)

· Lumen Depreciation:2.1% (L70 projection: 54,000 hours)

high-power-flood-light-certifications

FAQ

Q: How do I know the 1200W LED matches my current 2000W metal halide brightness?

The key metric is lumens, not watts. Our 1200W LED produces 156,000 lumens, while a typical 2000W metal halide delivers 140,000-160,000 lumens (after accounting for ballast losses and lumen depreciation).

Q: What happens if the fixture fails within 5 years?

We ship a replacement unit within 72 hours (free of charge, including international freight). Our failure rate is 0.3% based on 50,000+ units shipped since 2019. The warranty covers full replacement, not just repairs.

Q: Can this work with our 480V three-phase industrial power?

Not directly – the input range is 90-305V. For 480V, you'll need a step-down transformer (we can recommend compatible models). Alternatively, consider our 480V-input model (1500W version) designed for North American heavy industry.

Q: How do I clean fixtures installed 30 meters high?

The IP67 rating allows pressure washing up to 100 bar. For high installations, we recommend annual cleaning using lift equipment. The sealed design prevents internal dust accumulation – no need to open the housing.

Get Started: Three Ways to Contact Us

Contact our led high power flood light's team:sam@razorlux.com

Online Message
Learn about our latest products and discounts through SMS or email