Rated Power: 400W
Input Voltage: AC110-480Vac, DC100 ~ 400Vdc, 500Vdc ~ 800Vdc
Color Temperature: 2700K-6500K
Lamp Efficiency: 130LM/W
Beam Angle: 40°, 60°, 120°, 140°x60°.
CRI: Ra>75
IP Grade: IP65/IP67
Bracket: Stainless Steel
Net Weight: 15KG
Warranty: 5 Years
Certificate: CE, RoHS, SAA, C-Tick, UL, DLC, CB, ISO:9001
- Product Description
400 Watt LED Stadium Lights – Industrial-Grade High-Output Lighting
Razorlux offers 400 watt LED Stadium Lights to replace your energy-hungry 1000W–1500W metal halide lamps. These lights provide instant-on performance, flicker-free lighting, and energy savings of up to 70% with 52,000 lumens at 130LM/W efficiency. They are trusted at ports, sports facilities, and industrial sites in more than 40 countries because they are designed for severe conditions with IP67 protection and C5M marine-grade corrosion resistance. supported by a 5-year guarantee and more than 200 patents.

400 Watt LED Stadium Lights Specifications

Model | RGL2-400A | |
Beam Angle | 40° 60° 120° 140° | |
Stable Flux (5700K after 1 hour) | 52000lm | |
| LEDs | 360W |
Power | Driver | 40W |
Consumption | Total | 400W |
Replace HID Lamp | 800~1000W | |
Net Weight | 15kg with stainless steel floodlight bracket | |
Color Temperature | 2700-6500K | |
Color Rendering | ≥Ra75 (≥Ra80, ≥Ra90 available on request) | |
Working Life | ≥50000Hrs | |
Housing Material | Aluminum & Powder coating | |
Power Supply | Meanwell | |
IP Class | IP 67 | |
IK Class | IK 10 | |
Insulation Class | Class I | |
Working Temperature | -40C ~ 60C / -40F ~ 140F | |
Working Humidity | 10% ~ 95% | |
AC Input | 110-480Vac input voltage without additional adapter | |
DC Input | 100 ~ 400Vdc, 500Vdc ~ 800Vdc | |
THD | <10% | |
Power Factor | ≥0.98 | |
Warranty | LED Module | 5 years |
| Driver | 5 years |
| Housing | 10 years |

Product Overview
What Makes 400W LED Stadium Lights Essential?
Traditional HID lighting creates three critical problems for facility managers:
1. Energy waste: 1000W metal halide lamps consume excessive power while delivering inconsistent light quality
2. Maintenance burden: Frequent bulb replacements at unsafe heights raise labor expenses and safety hazards
3. Operational delays: Warm-ups lasting 15 to 20 minutes interfere with events and security procedures.
Solid-state technology is used by Razorlux 400W LED stadium lights to address these issues. Warm-up delays are eliminated with instantaneous full-brightness activation. The lifespan of more than 50,000 hours (10+ years at 12 hours per day) significantly lowers the frequency of maintenance. Even in extremes of -40°C to +60°C, constant output is maintained via advanced thermal management.
Precision optics that satisfy FIFA and IESNA regulatory requirements and offer seven beam angle settings (15° to 140°x60°) guarantee consistent coverage. Flicker-free, high-CRI lighting satisfies the standards for high-definition transmission.

Key Features & Applications
Energy Efficiency & Cost Savings
Maximum light output is achieved with low power consumption because to the 130 LM/W effectiveness. Energy is immediately reduced by 60% in facilities that replace 1000W metal halide bulbs. In regions with unstable power grids, a broad input voltage range (AC 90–305V) ensures stable operation.
Instant-On Performance
Full brightness as soon as you flip the switch is known as zero warm-up time. Crucial for:
- Emergency lights and security measures
- Sports occurrences that need to be illuminated right away
- Industrial activities where money is lost due to downtime
LED 400 watt led stadium lights restart immediately following power outages, in contrast to HID lighting, which take more than 15 minutes.
Broadcast-Quality Illumination
High-speed cameras can no longer detect flicker thanks to sophisticated constant-current drivers. Sports venues that hold recorded events and television broadcasters gain from:
- Capturing videos smoothly and without strobing effects
- Precise color rendering (CRI >75) for an authentic look
- Uniform lighting that satisfies broadcast requirements (>1000 lux vertical for HD)

Harsh Environment Durability
IP67 protection: Complete dust-tight seal with waterproof performance against temporary immersion
C5M marine certification: Salt-spray tested for coastal and offshore installations
Vibration resistance: Reinforced internal components withstand heavy machinery and high-wind environments
Thermal management: Precision-engineered heat sinks maintain junction temperature below critical thresholds
The marine-grade stainless steel mounting bracket resists corrosion in:
· Seaport terminals and shipyards
· Chemical processing facilities
· Coastal sports complexes
· Mining operations with corrosive dust
Flexible Optical Control
Seven beam angle options allow precise light distribution matching your mounting height and coverage requirements:
· 15°-30° (narrow beam): High-mast applications 20-40m, long-throw projection
· 40°-60° (medium beam): Standard mounting 10-20m, balanced coverage
· 120°-140°x60° (wide/asymmetric): Low mounting 6-12m, floodlight applications
Asymmetric optics reduce light trespass into residential areas while maximizing on-target illumination.
Sports Facilities
Municipal basketball, tennis, and pickleball courts must have consistent horizontal and vertical illumination and meet recreational (200 lux) to competitive (500+ lux) standards. Both player comfort and spectator visibility are guaranteed by the UGR<19 glare rating.
Amateur football and soccer fields: Replace current 1000W metal halide fixtures directly, one for one, without upgrading the electrical infrastructure. Pregame warm-up waits are eliminated by the instant-on function. Neighborhood concerns are addressed by reduced light spill.
Professional stadiums: HD/4K video production is supported by broadcast-quality lighting. Lighting levels may be adjusted for various event kinds thanks to the dimming functionality (0–10V, DALI).
Industrial & Commercial Sites
Port terminals: dependable operations for loading docks, container yards, and crane operations around-the-clock. Marine settings are tolerated by construction that is resistant to salt spray. Industrial power fluctuations are handled with wide voltage tolerance.
Mining operations: For dangerous areas, explosion-proof housing is offered. A vibration-resistant design withstands the impact of large machines. Cold-start capabilities for northern regions at -40°C.
High-bay warehouse lighting with consistent ground illumination is a logistics center. 24/7 facilities see less disturbance when maintenance is performed less frequently.
Perimeter illumination for military posts, prisons, and airports is one example of large-area security. Being able to react quickly is essential for emergency situations.

FAQ
Q: What's the actual equivalent to my 1000W metal halide fixture?
A: Our 400W LED delivers 52,000 lumens, matching or exceeding most 1000W metal halide systems (which output 40,000-50,000 lumens after depreciation). You get equal or better illumination with 60% energy savings.
Q: Can I install these in coastal salt-spray environments?
A: Yes. C5M marine certification and IP67-rated enclosures are specifically tested for extreme coastal exposure. The stainless steel brackets include additional corrosion-resistant treatment. Typical applications include seaports, offshore platforms, and beachfront facilities.
Q: How do I choose the correct beam angle?
A: Mounting height determines beam angle:
· 6-10m height: 120° or 140°x60° wide beams
· 10-15m height: 60° medium beam
· 15-25m height: 30°-40° narrow beams
· 25m+ high-mast: 15°-20° spot beams
contact us with your pole height and coverage area for photometric analysis.
Q: Do these support dimming and smart controls?
A: Yes. Available options include:
· 0-10V analog dimming (compatible with most building systems)
· DALI protocol for advanced lighting management
· DMX control for entertainment venues requiring dynamic effects
Integration with building management systems (BMS) enables scheduling and remote adjustment.
Q: Can you customize color temperature or beam patterns?
A: Yes. We provide custom solutions including:
· Specific color temperatures (2700K-6500K)
· Tunable white (adjustable CCT)
· Custom beam angles and asymmetric distributions
· Modified housing colors or finishes
· Specialized mounting brackets
Minimum order quantities apply for custom specifications.
Contact Us
Get technical support for your project. Our 400 watt led stadium lights specialists provide photometric analysis, installation planning, and customized solutions.
Email: sam@razorlux.com
VIEW MORELed Indoor Arena Lights
VIEW MORELed Flood Lights For Football Field
VIEW MORE500W Led Stadium Light
VIEW MOREFootball Field 140F Led Stadium Lights 1000 Watt 5700K Sports Lighting Fixtures
VIEW MORE500W Robust Heavy Duty LED Stadium Lights Arena LED Lighting
VIEW MORELED softball field lighting high mast flood light systems
VIEW MORE5700K Outdoor Garden Led Light Ip67 100000lm Flood Lights For Volleyball Court
VIEW MOREHot Products Aluminum Alloy floodlight 1000w led flood light for Indoor Outdoor Sports Venue

_1750326878398.png)